Product Details:
Payment & Shipping Terms:
|
Test Matrix: | Whole Blood/serum/plasma/milk | Storage: | Room Temperature |
---|---|---|---|
Assay Time: | 10-15 Min | Read Result: | Naked Eyes |
Packing: | 10/20/50 Tests Per Box |
(Whole Blood / Serum / Plasma / Milk)
INTENDED USE
African Swine Fever Virus Antibody Rapid Test (whole blood / serumr/ plasma/milk) is a solid phase immunochromatographic assay for the rapid,qualitative and dfferentia ldetection of antibody to animal whole blood serum, or plasma. This test provide only a preliminary analytical result. A secondary analytical method must be used to obtain a confirmed result. Gas chromatography and mass spectrometry (GC/MS) are the preferred confirmatory methods.
Naked eyes interpretation for Qualitative Results , Quantitative Analysis with machine.
PRINCIPLE
Quantitative or qualitative detection of the titer level of African porcine fever antibodies in samples using a double antigen sandwich method. During detection, the African swine fever antibodies in the sample binds to the colloidal gold-coated specific antigen fragment to form an antigen-antibody complex, which flows along the test paper to the other end of the NC membrane. When the complex flows to the T-zone on the membrane, the antigen immobilized on the membrane captures the complex and gradually agglutinates into a red visible T-line, while the unbound colloidal gold antibody flows through the T-zone and is captured by the secondary antibody in the C-zone and forms a visible red C-line.
KIT CONTENTS
NO. | NAME | PACKING |
1. | Rapid Test Cassette | 10/20/50 Tests |
2. | Plastic Dropper | 10/20/50 Tubes |
3. | Technical Manual | 1 Set |
STORAGE AND STABILITY
1. Store in a light-proof, dry environment (2-30℃).
2. DO NOT FREEZE or use beyond the expiration date.
3. The shelf life is 18 months.
QUALITATIVE ANALYSIS
1. Sample dilution to be tested: Pipette 35ml (or 1 drop) of serum sample, add to the sample dilution tube, gently invert up and down 10 times and mix thoroughly; The sample can be used for testing after dilution and can be stored for 1 day at room temperature.
2. Test card restored to room temperature: The test should be carried out at 20-30℃. If the test card is stored in a refrigerator (2-8℃), equilibrate it in a room temperature environment for 30 min before ripping the packaging inside the aluminum foil bag to avoid abnormal measurement results due to moisture absorption.
3. Test card number: After preparing the sample to be tested, remove the required test card and mark the sample number on the card.
4. Dropwise sample reaction for 20 min: Aspirate 70 ml of the serum sample to be tested, drop it into the sampling hole and leave it horizontally for 20 min.
READ RESULTS WITH NAKED EYES
NEGATIVE:
The Test Line (T) is the same as or darker than the Control Line(C). It is negative.
POSITIVE:
The Test Line (T) is lighter than the Control Line(C),or there is no Test Line. It is positive.
INVALID:Reference Line Fails to appear
Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for an invalid result.
Review the procedure and repeat the test with a new test kit. Stop using the test kit immediately if the problem
is not solved and contact your local distributor.
Bella@nkbiotech.com
Whatsapp: 0086-151-5809-6930
Tel.: 0086-151-5809-6930
Contact Person: Miss. Bella
Tel: 0086-151-5809-6930
Fax: 86-571-87114601