Nankai Biotech Co., Ltd.

sale@nkbiotech.com

WhatsApp:86-151-5809-6930

Sales & Support
Request A Quote - Email
Select Language
English
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsMilk Rapid Test Kit

Detection of Aflatoxin M1 Residue in Milk

Good quality Seafood Rapid Test Kit for sales
I'm Online Chat Now

Detection of Aflatoxin M1 Residue in Milk

China Detection of Aflatoxin M1 Residue in Milk supplier
Detection of Aflatoxin M1 Residue in Milk supplier Detection of Aflatoxin M1 Residue in Milk supplier Detection of Aflatoxin M1 Residue in Milk supplier Detection of Aflatoxin M1 Residue in Milk supplier

Large Image :  Detection of Aflatoxin M1 Residue in Milk

Product Details:

Place of Origin: China
Brand Name: NKBIO, SmarKIT
Certification: CE,ISO,TUV
Model Number: Aflatoxin M1

Payment & Shipping Terms:

Minimum Order Quantity: 1 kit(96 pieces)
Packaging Details: 96 tests/kit
Delivery Time: 1 working day
Payment Terms: T/T
Supply Ability: 200000 tests/month
Contact Now
Detailed Product Description

Nankai Biotech  Aflatoxin M1 Rapid Test Kit  is a rapid, one step test for the qualitative (or quantitative) detection of Aflatoxin M1 Residue in raw milk. 

Specifications
Principle: Lateral flow immunochromatographic assay
Intended use: Detection of Aflatoxin M1 residue in milk
Detection limit: 0.2 ppb
Reading time: 3 min
Shelf life: 12 months
Storage: room temperature(4-30℃), No freezing.
Packing size: 96 tests / box

SAMPLE PREPARATION

-Open the incubator, and make it to the temperature of 50℃.

-Suck 0.1ml milk sample into a colloidal gold micro-well and then incubate for 5 mins.

-Dissolve the red substance fully by using small dropper.

-Put the test strip into the colloidal gold micro-well, and incubate 5 mins.

-Take out the test strip and read the result.

Notes: The result should be read within 3 minutes. Do not interpret results after 3 minutes.

 

READING RESULTS BY EYES

Detection of Aflatoxin M1 Residue in Milk

NEGATIVE

The Test Line (T) is the same as or darker than the Control Line (C). It is negative.

POSITIVE

The Test Line (T) is lighter than the Control Line (C), or there is no Test Line. It is positive.

INVALID

INVALID: Reference Line fails to appear. 

Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for an invalid result. Review the procedure and repeat the test with a new test Kit. Stop using the test kit immediately if the problem is not solved and contact your local distributor.

 

 

NKBIO RAPID TEST Advantages:

1. 3-5 min reading results
2. Detection limits respond to EU and US FDA norms
3. Single test for every target sample
4. Neither professionals nor equipment required
5. Eyes interpretation or quantitative measurement,
suitable for lab and field use
6. Room temperature storage
7. Non-toxic and harmless

 

For more information, please contact bella@nkbiotech.com or visit http://www.foodrapidtest.com 

 

Detection of Aflatoxin M1 Residue in Milk

 

Contact Details
Nankai Biotech Co., Ltd.

Contact Person: Miss. Bella

Tel: 0086-151-5809-6930

Fax: 86-571-87114601

Send your inquiry directly to us (0 / 3000)